The ability to monitor indoor air continuously is changing how we understand exposure inside homes, schools, workplaces and other occupied spaces. Affordable sensors can reveal pollution events that conventional short-term measurements may miss, while making air-quality information accessible to researchers, building managers and even individual occupants. At the same time, their growing use raises important questions about calibration, accuracy, data reliability and how measurements should be translated into action.
This session explored that balance between accessibility and scientific robustness, showcasing long-term monitoring campaigns, sensor networks, personal exposure studies and targeted interventions, alongside emerging approaches for detecting biological contaminants.
Hanns Moshammer, Medical University of Vienna, with K-HEALTHinAIR partners
Three years of measurements in Austrian homes and schools provided an opportunity to examine both the strengths and limitations of affordable IAQ sensors. Temperature, humidity and CO₂ measurements performed relatively reliably, while more complex measurements such as VOCs and trace gases presented greater challenges.
The work highlights an important message for wider sensor deployment: low-cost devices can be extremely useful, particularly for identifying patterns and raising awareness, but access to raw data, regular calibration and careful interpretation remain essential if they are to support robust scientific assessment.
Maidá Domat, Universidad de Oviedo
Rather than relying on individual commercial monitors, this study developed a modular sensor network designed for continuous indoor and outdoor particulate monitoring in Gijón. Each node combines low-cost particulate and environmental sensors with long-range, low-energy data transmission, at a cost of less than €200 per unit.
Several units have already been deployed in classrooms, university facilities and outdoor locations, with four operating continuously for more than a year. The experience shows how affordable sensor networks can combine environmental monitoring with citizen science and education, provided that calibration, humidity effects, maintenance and communication infrastructure are properly addressed.
Mariusz Rogulski, Warsaw University of Technology, with K-HEALTHinAIR partners
Continuous monitoring at 23 locations across seven schools revealed two very different IAQ challenges. CO₂ rose sharply during school hours and was strongly connected with occupancy and insufficient ventilation, with maximum hourly concentrations exceeding 5,000 ppm in one school. PM₂.₅, by contrast, showed much less dependence on whether pupils were present and tracked outdoor pollution more closely.
This creates a difficult ventilation-filtration dilemma: opening windows can reduce accumulated CO₂ while simultaneously bringing polluted outdoor air inside. The findings suggest that schools may need approaches capable of managing ventilation and particle filtration together rather than treating them as separate issues.
İlknur Ayri, İzmir Institute of Technology
A classroom can also contain important differences from one side of the room to another. Using multiple low-cost sensors in a windowless university classroom in Türkiye, researchers monitored CO₂, particles, VOCs, formaldehyde and several environmental comfort parameters under different occupancy conditions.
CO₂ increased substantially when the room was occupied and occasionally exceeded 2,000 ppm. Spatial analysis also revealed a gradient, with better conditions close to the door and poorer conditions toward the rear of the classroom. The study shows why a single measurement point may not always capture the experience of everyone sharing the same room.
Francisco Javier Rey Martínez, University of Valladolid
Continuous monitoring can also help identify very specific occupational exposure events. At the Río Hortega University Hospital pathology laboratory, researchers monitored environmental and chemical parameters throughout a working day while simultaneously recording occupancy, work activities and the operation of extraction hoods.
Pollutant peaks were linked with factors including extraction performance, occupancy and chemical-intensive activities. The findings point directly toward practical measures such as improved fume-hood operation and maintenance, better general ventilation and adaptations to working practices.
Dominika Mucha, Warsaw University of Technology, with Austrian research partners
Continuous sensors become particularly powerful when their measurements can be linked to what people are actually doing. Residents in Poland and Austria recorded household activities while sensors monitored particles, VOCs, CO₂, humidity and temperature. The results revealed distinct signatures associated with sparkler candles, laundry drying and cooking.
A birthday sparkler produced the most dramatic event, with PM₂.₅ rising more than one hundredfold, while cooking increased both particles and VOCs and indoor laundry primarily affected VOCs. Importantly, pollution rose quickly but often took hours to return to baseline, showing why short activities can still make a meaningful contribution to overall exposure.
Sotirios Papathanasiou, GO AQS CIC
What happens when monitoring moves away from the building and follows the individual? Two portable monitors were carried for 367 days across different environments in Granada and Almería, measuring personal exposure to PM₂.₅ and CO₂.
The study revealed a recurring seasonal trade-off. Keeping windows closed during winter limited infiltration of outdoor particles but allowed CO₂ to accumulate, while greater summer ventilation reduced CO₂ but increased outdoor PM₂.₅ infiltration. It also exposed practical challenges associated with long-term consumer monitoring, including missing data and device reliability.
Alexandra Kristian, Medical University of Vienna, with K-HEALTHinAIR partners
Continuous sensors were also used to test whether portable air purification could make a measurable difference in occupied homes. Two wood-heated households with different source locations and exposure conditions were monitored while HEPA and combined HEPA/activated-carbon filtration were used.
Both homes experienced substantial reductions in PM₂.₅, including roughly 71% reductions during the HEPA-only periods. The study also showed that effectiveness cannot be reduced to the filter alone: purifier placement, operating level, building layout, room size and proximity to the pollution source all matter.
Dominik Heß, MANN+HUMMEL, with K-HEALTHinAIR partners
A second air-purification study asked a practical question: how robust are portable purifiers when faced with imperfect operation? Researchers tested different fan settings, filter conditions and potential user errors while comparing low-cost particle sensors with laboratory-grade equipment.
The purifier remained relatively robust even under several error scenarios. The experiments also showed that operating at higher power for shorter periods could be more energy-efficient, although noise becomes an important consideration in settings such as classrooms. Low-cost sensors successfully captured trends, but accurate absolute measurements required appropriate calibration.
Javier Diéguez-Uribeondo, Real Jardín Botánico-CSIC, with Mercedes Iriarte-Cela and Clara Pérez-Setién
Not every relevant indoor contaminant can be detected through the usual combination of CO₂, particles and VOC sensors. This contribution explored an electrochemical immunosensor for passive screening of airborne contamination associated with aflatoxin B1, a mycotoxin that can be produced by Aspergillus in fungal-contaminated environments.
The disposable sensor produced a concentration-dependent response and showed its strongest response after exposure to mature Aspergillus cultures. Although this represents a very different type of sensing technology from the low-cost monitors used elsewhere in the session, it points toward a future in which IAQ monitoring could encompass specific biological hazards as well as conventional environmental parameters.
The full Book of Abstracts of the "Healthy Indoor Congress" is available here.