Indoor Pollutants and Microbiome Dynamics

Indoor Pollutants and Microbiome Dynamics

Indoor air is shaped by an extraordinary combination of factors: the pollutants generated inside buildings, what enters from outdoors, how people use and ventilate spaces, and the microorganisms continuously circulating through them. This wide-ranging session explored these interactions across homes, schools, hospitals, public spaces and other real-world environments, while also examining new methods and technologies for measuring, understanding and reducing indoor contamination.

Together, the contributions show that indoor air cannot be understood through a single pollutant or measurement. Its quality emerges from the interaction between buildings, human activity, outdoor conditions, chemical pollutants and biological communities, calling for equally integrated approaches to assessment and intervention.

Understanding pollution in real indoor environments

A European picture of indoor air across different settings

Carla Martins and K-HEALTHinAIR partners

Drawing directly on K-HEALTHinAIR monitoring, this multi-country analysis compared CO₂, particulate matter and formaldehyde across homes, schools, canteens, lecture halls, hospitals, markets and metro environments in six countries. The results showed how strongly indoor activities, household characteristics and season can influence exposure, with notable CO₂ exceedances in schools and particulate pollution in homes associated with factors including smoking, cooking and heating.

This would be a particularly good opening abstract for the session, because it establishes the broad European picture before we move into more specific environments.

How residential heating shapes PM₂.₅ exposure

Piotr Kępa, Warsaw University of Technology, with K-HEALTHinAIR partners

Two years of continuous monitoring across 27 Polish homes revealed a clear gradient in indoor PM₂.₅, with average concentrations highest in homes using solid fuels, followed by gas-heated and non-combustion homes. But heating technology told only part of the story. Cooking, smoking, individual building characteristics and infiltration of outdoor pollution could produce substantial differences even between homes using the same type of heating.

The study highlights why reducing residential exposure requires attention not only to the heating system itself, but also to the wider building, neighbourhood and occupant context.

When opening the window creates another problem

Marta Sacristán-Uña, University of Valladolid

During a heatwave, opening windows may be essential for thermal comfort. But what happens when the outdoor air is affected by wildfire smoke or desert dust? Monitoring in 22 bedrooms in social housing in Valladolid explored precisely this tension. These homes had no dedicated ventilation systems and depended largely on occupants opening windows for air exchange.

Preliminary findings showed that when windows were opened and indoor CO₂ fell, particulate matter could initially rise as outdoor pollution entered the dwelling. The work therefore reveals a potentially important double vulnerability in ageing social housing: overheating indoors versus exposure to outdoor pollution brought in through natural ventilation.

Following VOCs through the metro and the market

Alberto Rodríguez López, CIEMAT, with K-HEALTHinAIR partners

Metro stations and public markets sit somewhere between indoor and outdoor environments, making them particularly interesting spaces for understanding pollutant movement. Seasonal monitoring in Barcelona found a strong outdoor influence on VOC concentrations at Barceloneta metro station, while conditions in La Concepció market varied much more depending on local ventilation.

The least ventilated area of the market consistently accumulated the highest VOC concentrations, whereas its open flower shop resembled outdoor conditions. The findings underline ventilation as a major determinant of pollutant distribution in busy urban spaces.

Microbes, PAHs and the seasonal challenge inside schools

Adam Muszyński and Artur Badyda, Warsaw University of Technology

Research in five Polish primary schools examined both biological contamination and polycyclic aromatic hydrocarbons, showing that these pollutants respond differently to people, ventilation and season. Poorly ventilated occupied classrooms contained substantially higher bacterial concentrations, while fungi increased during summer and PAHs were more prominent during the winter heating period.

The findings capture one of the recurring challenges running through this entire session: ventilation can reduce pollutants generated indoors while simultaneously allowing outdoor pollutants to enter. In this case, opening windows helped reduce bacteria but could contribute to fungal exposure in summer and PAH exposure in winter.

The invisible ecosystems in the air around us

Every urban environment has its own airborne microbiome

Clara Pérez-Setién and colleagues

Are the microorganisms in the air of a hospital the same as those found in a metro station or public market? Sampling across Barcelona showed clearly distinct bacterial and fungal communities between the three environments. A common microbial core was present, but each setting also carried its own ecological signature.

Human-associated microorganisms were more characteristic of hospitals, plant-associated taxa of markets, and organisms linked with urban dust of metro environments. The work demonstrates that the places we build and use do not simply contain microorganisms. They actively help shape the airborne microbial communities to which people are exposed.

What happens to the microbiome when a judo class begins?

Nina Doskocz, Warsaw University of Technology

Indoor sports facilities offer a particularly dynamic example of how human activity changes the air. Samples taken before and after training sessions in a Polish judo hall showed increasing bacterial diversity as activity intensified, alongside changes in both bacterial and fungal community structure.

Before training, environmental bacteria were more prominent. Afterwards, human-associated genera became increasingly visible, illustrating how movement, occupancy and contact with indoor surfaces can quickly reshape the microorganisms suspended in indoor air.

Bringing the microbiome and antimicrobial resistance into IAQ monitoring

Sofya Pozdniakova and colleagues

Healthcare air monitoring usually concentrates on particles, gases and environmental conditions. This study extended that picture by combining aerosol measurements with metagenomics, microbiological culture and antimicrobial-resistance profiling in an elderly care centre and hospital in Greece.

Researchers identified bacterial, fungal, archaeal and viral signatures as well as multiple antimicrobial-resistance determinants, including viable bacteria displaying multidrug-resistant phenotypes. The work makes a strong case for considering biological indicators alongside traditional physicochemical measurements when assessing complex healthcare environments.

When a pollution-control technology becomes a microbial source

Katarzyna Affek, Warsaw University of Technology

Biofilters are widely used to clean industrial waste gases, but their microbial bed material means they can also release microorganisms themselves. Tests at three industrial sites in Poland showed that whether a biofilter reduced or increased bioaerosols depended strongly on the microbial content of the incoming waste gas.

Under high inlet contamination the filters could reduce microbial concentrations, while at sites with cleaner incoming gas they sometimes became net emitters of bacteria and fungi. The results show why biological emissions also need to be considered when evaluating air-treatment technologies.

Measuring and removing chemical pollutants

From the room to the laboratory: making VOC measurements reliable

Raúl Matesanz Sanz, CIEMAT

Good indoor air science depends on what happens long before the final laboratory result appears. This contribution presented a complete workflow for sampling and analysing VOCs using thermal desorption and GC-MS, covering everything from sorbent-tube preparation and controlled sampling to transport, storage, traceability and quality assurance.

The main message is simple but important: sophisticated instruments alone cannot guarantee reliable evidence. A carefully controlled analytical chain is essential if results from different campaigns, buildings and locations are to remain comparable.

Choosing the right technology for the right pollutant

Stefan Schumacher, IUTA

Particles, gases and microorganisms behave differently, which means there is no single air-cleaning technology that performs equally well against them all. This contribution compared filtration, electrostatic methods, adsorption, photocatalytic approaches and UV-based treatment while highlighting practical considerations such as airflow, energy demand, maintenance and secondary pollutants.

The work also stresses that apparent pollutant removal is not enough. Technologies that chemically transform pollutants need to be assessed for potential by-products, while UV systems must be evaluated according to delivered dose, occupant safety and possible ozone generation.

Can plants and their microorganisms clean indoor air together?

María Sol Montaluisa Mantilla, University of Valladolid

Botanical filtration offers a very different approach to IAQ management. Experiments with five indoor plant species investigated how leaves, roots and root-associated microorganisms contribute to removing VOCs including acetone, toluene, α-pinene, xylene and limonene.

Whole plants consistently performed better than foliage alone, while root-associated microorganisms also made a substantial contribution. The results suggest that the effectiveness of botanical filters comes from the interaction between physical adsorption, plant uptake, metabolic processes and microbial degradation, rather than from the leaves alone.

Turning organic residues into materials for cleaner air

Andrea Medina, CIEMAT

Can waste streams become materials for carbon capture and pollutant removal? This research transformed digestates from anaerobic co-digestion into modified biochars and combined them with graphitic carbon nitride to create multifunctional adsorbent-photocatalyst materials.

The modified biochars showed strongly enhanced CO₂ adsorption, while the hybrid material improved the stability of photocatalytic degradation of gaseous trichloroethylene. The study connects circular economy principles with the development of new materials for air-pollution mitigation.

Finding the right balance for formaldehyde removal

Tore Sandnes Vehus, University of Agder, with CIEMAT

Another materials-focused contribution investigated how KOH treatment and spruce biochar could improve TiO₂-based removal of formaldehyde. The experiments showed that stronger chemical treatment did not automatically produce better overall performance: the optimal condition depended on the balance between pollutant adsorption and photocatalytic activity.

For the biochar-TiO₂ composite, moderate KOH treatment provided the strongest combined performance, illustrating the importance of designing materials in which adsorption and photocatalytic oxidation work together rather than compete.

Moving from pollutant removal to active biological decontamination

Using UV-C to target microorganisms in air and on surfaces

María Victoria García-Gallardo Sanz, Healthy Indoor Technology

This study evaluated a patented UV-C system designed to reduce biological contamination in both air and on surfaces. Controlled experiments achieved reductions greater than three log units for Leuconostoc mesenteroides and more than four log units for E. coli, with airborne concentrations dropping rapidly during treatment.

Alongside the biological results, the work developed a more reproducible methodology for evaluating UV-C systems, recognising that factors such as source stabilisation, aerosol behaviour and physical deposition can otherwise distort estimates of effectiveness.

Catalytic filters that inactivate rather than simply capture pathogens

Paula Llanos Fdz-Valmayor, CSIC

Instead of trapping microorganisms inside a filter, this work explored catalytic materials designed to inactivate pathogens through oxidative stress. Copper-based ceramic filters demonstrated broad activity against several viruses and bacterial species, including coronaviruses, rhinovirus, E. coli and S. aureus.

Laboratory results showed reductions of around four log units, while aerosol-chamber experiments achieved reductions of up to eight log units. The filters also retained antimicrobial activity after repeated use and after one year of storage, supporting further investigation of their potential integration into air-treatment systems.

From the laboratory to a real hospital

Gonzalo Sánchez Domínguez, CSIC, with Hospital Universitario La Paz

A second photocatalytic approach followed the technology through several increasingly realistic stages: laboratory pathogen testing, aerosol chambers, room-scale experiments and finally deployment in the waiting room of a paediatric emergency department. The system combined a photocatalytic nanofibre filter with UV-A illumination and active airflow.

The material demonstrated broad antimicrobial activity and substantial reductions in infectious airborne viruses under experimental conditions. During real hospital deployment, bacterial and fungal concentrations were reduced relative to the control configuration, while the system operated without disrupting normal clinical activity.

 

The full Book of Abstracts of the "Healthy Indoor Congress" is available here.